特点 国际通用交流输入 保护种类:短路/过负载/过电压 自然冷风 LED电源指示 开关切换频率:50KHz 2年保固
| |
电气规格 |
| |
型号 |
T-60A |
T-60B |
T-60C |
输出 |
输出编号 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
直流电压 |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
额定电流 |
5A |
2.5A |
0.5A |
5A |
2.5A |
0.5A |
5A |
2A |
0.5A |
电流范围 |
0.5~7A |
0.2~3.5A |
0~1A |
0.5~7A |
0.2~3.5A |
0~1A |
0.5~7A |
0.2~3A |
0~1A |
额定功率 |
57.5W |
61W |
62.5W |
纹波与噪声(最大)备注2 |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
电压调整范围 |
CH1:4.75~5.5V |
CH1:4.75~5.5V |
CH1:4.75~5.5V |
电压精度备注3 |
±2.0% |
±6.0% |
±6.0% |
±2.0% |
±6.0% |
±6.0% |
±2.0% |
±6.0% |
±6.0% |
线性调整率 |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
±1.0% |
±0.5% |
负载调整率 |
±1.0% |
±4.0% |
±1.0% |
±1.0% |
±4.0% |
±1.0% |
±1.0% |
±4.0% |
±1.0% |
启动、上升时间 |
300ms, 50ms/230VAC 800ms,50ms/115VAC(满载时) |
保持时间(Typ.) |
80ms/230VAC 10ms/115VAC(满载时) |
输入 |
电压范围 |
85~264VAC 120~370VDC |
频率范围 |
47~63Hz |
效率(Typ.) |
72% |
72% |
72% |
j交流电流(Typ.) |
2A/115VAC 1A/230VAC |
浪涌电流(Typ.) |
20A@115V, 40A@230VAC冷启动 |
漏电流 |
<3.5mA/240VAC |
保护 |
过负载 |
额定输出的105%~150%动作 |
保护模式:打嗝模式,负载异常条件移除后可自动恢复 |
过电压 |
5V: 5.75~6.75V |
保护模式:打嗝模式:电压异常条件移除后可自动恢复 |
环境 |
工作温度 |
-10~+60℃(请参考负载减额曲线) |
工作湿度 |
20~90%RH,无冷凝 |
储存温度、湿度 |
-20~+85℃,10~95%RH |
温度系数 |
±0.03%/℃(0~50℃)(+5V) |
耐振动 |
按X、Y、Z轴进行,10~500Hz,2G 10分钟/周期,共60分钟 |
安规 和 电磁 兼容 (备注4) |
安全规范 |
UL1012, UL60950, TUV EN60950认证通过 |
耐压 |
I/P-O/P:3KVAC、I/P-FG:1.5KVAC、O/P-FG:0.5KVAC |
绝缘阻抗 |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
电磁干扰 |
符合EN5022(CISPR22)Class B |
谐波电流 |
符合EN61000-3-2, -3 |
电磁耐受 |
符合EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,EN55024, 轻工业等级A级标准 |
其它 |
MTBF |
28.1.1K hrs min. MIL-HDBK-217F(25℃) |
尺寸 |
159*97*38mm(L*W*H) |
包装 |
0.55Kg; 24pcs/14.2Kg/0.82CUFT |
备注 |
1.如未特别说明,所有规格参数均在输入为230VAC、额定负载、25℃环境温度下进行两侧。 2.纹波和噪声测量方法:使用一条12"双绞线,同时终端要并联0.1uf和47uf的电容,在20MHZ带宽下进行量测。 3.精度:包含设定误差、线性调整率和负载调整率。 4.电源被视为系统内元件的一部分,需结合终端设备进行电磁兼容相关确认 | | |